Service difficulty report · Relay · Boeing 777222

Difficulty date
October 15, 2012
Submitted
November 9, 2012
Operation
Air carrier
Aircraft
N778UA
Make and model
Boeing 777222
Aircraft serial
26940
Aircraft time
67,031 hours, 11,798 cycles
Engine
Pwa PW4077
Part
Relay
Part number
406171383
Condition
Faulty
Location
Electrical Sys
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ELEC STANDBY SYSTEM STATUS MESSAGE. MAT SHOWS MAINTENANCE MSG 24-13037 (RELAY DC TIE IN P210 NOT IN COMMANDED POSITION). ACPD FIM 24-32 TASK 802 CHECKED 28 VDC AT PIN 2 ON CB K9 P310, OKAY. RESET CB C24666 AT P210 REF WDM 24-32-11, MSG CLEARED, HOWEVER, MSG CAMES BACK DURING DC SYSTEM TEST. NEEDS TO REPLACE DC TIE RELAY (K24013) PCN 566-1103. REPLACED DC TIE RELAY, INSTALLATION TEST PASSED. OPERATIONAL TEST ALSO PASSED.