What was found
BS 1582 LAP SEAM APPEARS TO BE UNEVEN, ENTIRE CIRCUMFERENCE OF FUSELAGE, AFT PRESSURE BULKHEAD ATTACHMENT POINT. MAINT TEXT: ACCOMPLISHED ALL REQUIRED INSPECTIONS AND ACCOMPLISHED STRINGER SHIMMING REPAIRS AT THE FOLLOWING LOCATIONS: SECTION 46, STR'S 3R, 12R, 14R, 14L, 34L: AND SECTION 48, STR'S 3R, 6R, 12R, 14R, 24R, 29R, 31R, 33R, 39R, 12L, 14L, 19L, 24L, 32L, 34L, AND 39L PER REO G-15401, REV L AND EC-RA 5361-01028.