What was found
APU WILL NOT START, APU BATTERY CHARGER ON EICAS. REPLACED APU BATTERY PER AMM, OP CHECK OKAY. BATTERY CHARGING NORMALLY, NO MESSAGES. REPAIR- :BLED FUEL LINE PER MM 28 25 00, AFTER BLEEDING FUEL LINE APU STARTED 5X WITH NO ISSUES. APU OPERATED IN ALL MODES, NO FAULTS NOTED.