As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXTERNAL PROTRUSION AT BS 1600 PLUS 17, 1.25 INCHES BELOW STR 27R. MAJOR REPAIR ACCOMPLISHED: EXTERNAL FUSELAGE DENTED AT STA 1600 PLUS 17 1.25 INCHES BELOW STR 27 MEASURED DEPTH Y= .035, AY=32.5. DENT FOUND TO BE WITHIN LIMITS PER SRM 53-00-01 FIG 101 SHEET 4 DETAIL III. ACCOMPLISHED HFEC NO CRACKS NOTED.