As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN FLOORBEAM TEE CORRODED BS 324 RBL 39-61. REMOVED CORROSION, MATERIAL LOSS EXCEEDED SRM LIMITS. FABRICATED & INSTALLED TEE SPLICE REPAIR FROM BL 0 TO RBL 65 IAW SRM 53-10-08 REPAIR 1. FORMED ANGLE REPAIR FROM RBL 39 TO RBL 61 WITH STRAP SPLICE AT RBL 39.