What was found
FUSELAGE CREASE APPROX 1 FT AFT OF DOOR 3R AT MID LEVEL. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN DENT IS SMOOTH, CRACK FREE & WITHIN LIMITS PER SRM 53-00-01PG101. NO ACTION REQUIRED. DAMAGE WAS AT STA 1707, BETWEEN STR 15R & 16R. FOUND TO BE OUT OF LIMITS. DOUBLER REPAIR INSTALLED PER SRM 53-00-01 REPAIR 3 FIGURE 201.