As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND TWO DENTS JUST FORWARD OF NOSE GEAR DOORS. APPROX STATION 220 BELOW WATER LINE 199.8. ACCOMPLISHED HFEC INSP PER NDT MM 51-00-01 PART6, AND ECRA# 5330-04309, NO CRACKS NOTED. REMOVED DAMAGE. INSTALLED EXTERNAL DOUBLER REF SRM 53-00-01 RPR 1. INSTALLED STRINGER Z-ANGLE REPAIR PER SRM 53-00-03 RPR 4.