Service difficulty report · Controller · Boeing 767322

Difficulty date
December 5, 2012
Submitted
December 28, 2012
Operation
Air carrier
Aircraft
N644UA
Make and model
Boeing 767322
Aircraft serial
25094
Aircraft time
91,206 hours, 14,491 cycles
Engine
Pwa PW4060
Part
Controller
Part number
11518661
Part serial
215081C0316
Condition
Faulty
Location
Cabin Temp
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NEED TO REPLACE ZONE TEMP CONTROLLER DUE TO FWD, MID, ZONE TEMP FAULT. VERY ERRATIC ON ECS PAGE. VERY ERRATIC ON ECS PAGE. REPLACED ZONE TEMP CONTROLLER. FWD AND MID CABIN TEMPS ROSE TO 76 AFTER 30 MIN AT 69. MOVED CTRL SLIGHTLY, NOW BACK TO 69. FWD AND MID INDICATE INOP,NO ECS PAGE TRIM VALVE POSITION VALUES FOR AUX FWD,FWD,AUX MID,MID.FLIGHT DECK TRIM AIR WORKS IN MANUAL,INOP IN AUTO. AFT INDICATES OK. REPLACED K238 RELAY. REPLACED ZONE TEMP CONTROLLER, OPS CHECK AND BITE NORMAL.