What was found
STAR DEPARTURE CHECK REVEALS OVERWING SLIDE LIGHTS AT 2R, 3R, AND OVERWING AFT ARE INOP ON LIGHT TEST. RELAMPED DOOR 2R EXT EMERGENCY LIGHT, CHECK OK. DOOR 3R HAS POWER & GRD. RELAMPED, NO HELP. NEEDS REFLECTOR SOCKET, OVERWING RT AFT EMERGENCY LIGHT HAS 6.8VDC AND GROUND, RELAMPED NO HELP. LIGHTS LOCATED 5 WINDOWS AFT OF RT AFT OVERWING EXIT DOOR. DOOR 3RT OUTSIDE EMER LIGHT L60 NEEDS LAMP ASSY (LT INTERMITTANT) P-N 30-1672-2 OVERWING AFT OUTSIDE EMER LIGHT NEEDS LIGHT ASSY P-N 30-2537-2.