As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT LAVATORY SERVICE PANEL PAN IS DENTED AT SERVICE CONNECTION AREA. HFEC INSPECTION ACCOMPLISHED PER NTM PART 6 51-00-21, NO DEFECTS NOTED. REPLACED PAN WITH NEW PER ECRA 5300-01457 AND DRAWING 146N3650. COMPLETED INSTALLATION REF DRAWING 146N3650.