What was found
DENT AT BS 1842 JUST FWD OF APU FIRE EXTINGUISHER ACCESS. CUT OUT DAMAGED AREA, PERFORMED NDT, FABRICATED REPAIR PARTS, FILLER AND DOUBLER. TREATED AND PRIMED. INSTALLED REPAIR IAW SRM 53-00-01. NO CRACKS FOUND. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT AT BS 1842 JUST FWD OF APU FIRE EXTINGUISHER ACCESS. CUT OUT DAMAGED AREA, PERFORMED NDT, FABRICATED REPAIR PARTS, FILLER AND DOUBLER. TREATED AND PRIMED. INSTALLED REPAIR IAW SRM 53-00-01. NO CRACKS FOUND. MAJOR REPAIR.