What was found
GALLEY G2A FAILS ELECTRICAL BONDING CHECK REF JIC 525005050 AT C-6 VISIT. CLEANED BONDING SURFACES, REPLACED TWO TERMINALS ON WIRE 9005-08 AND BOND CHECKED GOOD IAW SWPM20-20-0, A ND 20-30-11. WDM 25-31-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GALLEY G2A FAILS ELECTRICAL BONDING CHECK REF JIC 525005050 AT C-6 VISIT. CLEANED BONDING SURFACES, REPLACED TWO TERMINALS ON WIRE 9005-08 AND BOND CHECKED GOOD IAW SWPM20-20-0, A ND 20-30-11. WDM 25-31-21.