What was found
CORROSION ON FLOORBEAM AT BS 1681 BL 0. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. REMOVED, FABRICATED NEW, AND INSTALLED NEW FLOORBEAM IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT BS 1681 BL 0. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. REMOVED, FABRICATED NEW, AND INSTALLED NEW FLOORBEAM IAW SRM 51-40-02.