What was found
MAIN CABIN FLOOR SUPPORT WEB UPPER ATTACH ANGLE HAS CRACKS AROUND FASTENER HOLES BETWEEN BS 1320 AND 1340 BL 0. REMOVED AND REPLACED FLOOR SUPPORT UPPER ANGLE IAW SRM 51-40-02 PAR 4 FIG 3. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR SUPPORT WEB UPPER ATTACH ANGLE HAS CRACKS AROUND FASTENER HOLES BETWEEN BS 1320 AND 1340 BL 0. REMOVED AND REPLACED FLOOR SUPPORT UPPER ANGLE IAW SRM 51-40-02 PAR 4 FIG 3. MAJOR REPAIR.