What was found
LEFT SIDE OF FUSELAGE JUST AFT OF DOOR 1L. AREA INSPECTED 2" DENT FOUND BETWEEN STATION 560 AND 580 BELOW S28L WITH TWO SCRATCHES-GOUGE MARKS APPROX 1.5" AND .5" BETWEEN .030 AND .050 DEEP. REPAIR COMPLETED AS PER SRM 53-00-01 REPAIR 1 PG 202 BLIND FASTENER REPAIR.