What was found
NEED TO PERFORM LAND VERIFY, DUE TO CHANGE OF RIGHT AOA VANE AND LM5625 AND CH0639. PERFORMED LAND VERIFY IAW AMM 22-97-00, LAND VERIFY TEST PASS, AC REMAINS IN FULL CAT CAPABLE I STATUS. R&R FO'S AOA & PHC IAW AMM, INSTALLATION ONLY. SEE SMC1 FOR O 'S CHKS THAT FAILED WHEN IR2 SELECTED 2 ON. SHOWING PARTS R&R AND MRDATA TRANSACTIONS ONLY. T-S FOUND RT AOA AT FAULT. RANDR IAW AMM TASK 341119000001, OPS CHK GOOD.