What was found
TWO INCH DIA AREA OF DISBOND ON LWR SURFACE OF NR 10 SLAT T/E WEDGE 8 INCHES FROM T/E AND 20 INCHES FROM O/B EDGE. REPAIR DISBONDED AREA ON LOWER SURFACE OF NR 10 SLAT T/E WEDGE 8 INCHES FROM T/E AND 20 INCHES FROM O/B EDGE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO INCH DIA AREA OF DISBOND ON LWR SURFACE OF NR 10 SLAT T/E WEDGE 8 INCHES FROM T/E AND 20 INCHES FROM O/B EDGE. REPAIR DISBONDED AREA ON LOWER SURFACE OF NR 10 SLAT T/E WEDGE 8 INCHES FROM T/E AND 20 INCHES FROM O/B EDGE.