What was found
UPPER RUDDER CONTROL MODULE MOUNT TRUNNION LOWER RIGHT ATTACH BORE IS GOUGED AND SCORED. CHIPPED AREA DIMENSIONS, .250 X .150 WITH A DEPTH OF .140. BLENDED GOUGED AREA FROM BOLT THREADS OUT TO .015" OVER FROM .312", DEPTH INTO BORE .312". NEEDS EDDY CURRENT INSP AND EG APPROVAL TO CONTINUE FOR RUD PCU INSTALLATION. ACCOMPLISHED EDDY CURRENT OF INNER BORE PER NDT MANUAL PART 6, 51-00-00, PROCEDURE 11.