As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CREW REPORTED NR 1 ENGINE EGT OVERLIMIT DURING START. NO RED TIC MARK DISPLAYED. INTERROGATED CFDS AND NO LIMITS EXCEEDED. ACCOMPLISHED MANUAL ENGINE START AND EGT WENT TO 625 AND ABORTED START WITH EGT OVERLIMIT AND START FAULT. REPLACED 7TH STAGE BLEED VALVE PER MM. RAN ENG NORMAL START. 7TH STAGE VALVE WAS LOWER LEFT.