What was found
APU CONTROL STATUS MESSAGE DISPLAYED ON LOWER EICAS. FOUND SPEED SENSOR NR 2 CIRCUIT FAILED AND SPEED SENSOR NR 2 LOWER THAN SENSOR 1. CLEANED AND SECURED SPEED SENSOR 2 CONNECTOR IAW AMM 49-61-02. RAN APU TEST, NO FAULTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU CONTROL STATUS MESSAGE DISPLAYED ON LOWER EICAS. FOUND SPEED SENSOR NR 2 CIRCUIT FAILED AND SPEED SENSOR NR 2 LOWER THAN SENSOR 1. CLEANED AND SECURED SPEED SENSOR 2 CONNECTOR IAW AMM 49-61-02. RAN APU TEST, NO FAULTS.