What was found
CIRCUIT BREAKER A14 TRIPPED, LOSS OF LT TANK NR 1 FUEL PUMP AND LOSS OF RT TANK NR 1 FUEL PUMP. ELEC PAGE INDICATIONS NORMAL. REPLACED A14 CIRCUIT BREAKER IAW AMM 28-21-00, TRANSFERRED FUEL, OPS CHECKED OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CIRCUIT BREAKER A14 TRIPPED, LOSS OF LT TANK NR 1 FUEL PUMP AND LOSS OF RT TANK NR 1 FUEL PUMP. ELEC PAGE INDICATIONS NORMAL. REPLACED A14 CIRCUIT BREAKER IAW AMM 28-21-00, TRANSFERRED FUEL, OPS CHECKED OKAY.