What was found
FLOORBEAM BS 1640 HAS CORROSION ON UPPER TEE REPAIR FROM RBL 15 - 65. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL III. REPAIRED IAW SRM 53-00-51 FIG 101 DETAIL III. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM BS 1640 HAS CORROSION ON UPPER TEE REPAIR FROM RBL 15 - 65. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL III. REPAIRED IAW SRM 53-00-51 FIG 101 DETAIL III. MAJOR REPAIR.