What was found
DISBONDED NR 9 SLAT UPPER SURFACE T/E WEDGE 29 INCHES FROM O/B, 6 INCHES FROM AFT. REPAIRED IAW SRM 51-70-10 REPAIR 4 FIGURE 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DISBONDED NR 9 SLAT UPPER SURFACE T/E WEDGE 29 INCHES FROM O/B, 6 INCHES FROM AFT. REPAIRED IAW SRM 51-70-10 REPAIR 4 FIGURE 201.