Service difficulty report · Circuit Breaker · Boeing 767322

Difficulty date
May 3, 2013
Submitted
June 19, 2013
Operation
Air carrier
Aircraft
N652UA
Make and model
Boeing 767322
Aircraft serial
25390
Aircraft time
90,064 hours, 14,295 cycles
Engine
Pwa PW4060
Part
Circuit Breaker
Condition
Tripped
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED CIRCUIT BREAKER G17 ON P11 TRIPPED SHORTLY AFTER TAKEOFF. G17 FOR 1R CSEU AC PWR SUPPLY. RESET NOT ATTEMPTED DUE TO POWER SUPPLY 2R POWERING THE CSEU. RERACK CSEU POWER SUPPLY AND CHECK PINS ALL OK RESET CIRCUIT BREAKER. CIRCUIT BREAKER STAYED IN, NO FAULT BALLS, TEST POWER SUPPLY AS PER MM, ALL OK.