What was found
FLOORBEAM BS 365 CORRODED FROM RBL 4 TO 57. CUTOUT DAMAGE SECTION OF UPPER TEE, INSTALLED ATTACH ANGLE AND STRAPS AT BS 365 LBL 12- RBL 6 IAW ECRA 5310-05536, AND SRM 51-40-02. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM BS 365 CORRODED FROM RBL 4 TO 57. CUTOUT DAMAGE SECTION OF UPPER TEE, INSTALLED ATTACH ANGLE AND STRAPS AT BS 365 LBL 12- RBL 6 IAW ECRA 5310-05536, AND SRM 51-40-02. MAJOR REPAIR.