As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EICAS MSG RT GEN OFF DISPLAYED. RT GENOFF&FIELD OFF LGT'S ILLUM. OPERATED NORM AFTER RESET. RT ENG GENERATOR TRIPPED OFF LINE ON TAKEOFF ABOUT 200 FT RESET NORMALLY. REPLACED NR 2 ENG IDG OIL OVERFLOW COUPLING REF AMM SUB TASK 24-11-01-434-033. RAN ENG AT IDLE FOR 10 MIN, NO LEAKS.