What was found
BLEED LOOP 2 BODY STATUS MESSAGE DISPLAYED ON EICAS. M LOOP 2, ZONE 18 IS SHORTED. TROUBLESHOT PER FIM 26-18 TASK 804. R & R NR 2 BODY LOOP DETECTOR IAW AMM 26-18-04. OPS CHECKED NORMAL, STATUS MESSAGE CLEARED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.