As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GREEN SYS QTY WAY BELOW MINIMUM. FOUND LEAK AT MANIFOLD GROUND SERVICE VALVE. REMOVED GROUND LEAKAGE MEASUREMENT MANIFOLD OF GREEN HYD SYS IAW MM. INSTALLED GROUND LEAKAGE MEASUREMENT MANIFOLD OF THE GREEN HYD SYS IAW MM, OPS AND LEAK CHECKED GOOD.