What was found
"Y RESERVOIR LO LEVEL" DISPLAYED ON UPPER ECAM SCREEN. FOUND HYD LINE LEAKING AT CLAMP. 12 O'CLOCK POSITION, JUST INBD OF HUGE PURPLE HYD CONNECTOR ON ENG NR 2. FOUND LINE UNDER CLAMP WITH CRACKED. REPLACED LINE. SERVICED YELLOW HYD'S AND MOTORED ENGINE, NO LEAKS FOUND.