What was found
RIGHT INBD MAIN FLAP LOWER SURFACE HAS A DENT 3 INCHES WIDE BY 5 INCHES LONG BY .083" DEEP. FOUND WITHIN LIMITS IAW SRM 57-53-01. REPAIRED RT INBD MAIN FLAP LWR SURFACE IAW SRM 51-71-10 REPAIR 4, FIG 202, SHEET 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT INBD MAIN FLAP LOWER SURFACE HAS A DENT 3 INCHES WIDE BY 5 INCHES LONG BY .083" DEEP. FOUND WITHIN LIMITS IAW SRM 57-53-01. REPAIRED RT INBD MAIN FLAP LWR SURFACE IAW SRM 51-71-10 REPAIR 4, FIG 202, SHEET 3.