What was found
AVIONICS SMOKE DISPLAYED, RTFL, NO PERCEPTIBLE SMOKE. SUSPECT POSSIBLE AEVC PCN 482-9059, COA 408151, ACCOMPLISHED REF TO EA 2100-01264 FOR AEVC REPLACEMENT. REF: TSM26-15-00-810-803-A (1WA) AVONICS SMOKE DET OPBLM FIELDS. REPLACED AEVC IAW 21-26-3 4 AND FWC NR1 IAW 31-53-34, OPS CHECKED OK. LAND CAT 3 TEST OK IAW AMM 22-97-00-710-001. ACFT REMAINS FULL CAT STATUS.