What was found
MAIN CABIN BS 1681, LBL 52 FLOORBEAM ANGLE HAS CORROSION BS 1681, LBL 52. REPAIR IN COMPLIANCE WITH NON ROUTINE NR 20419. R & R ANGLE IAW SRM 51-40-02, PAR 7, FIG 12. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT IAW SRM 51-40-02, PARA 7, FIG 12.