What was found
PASSENGER CABIN BS 1640, RBL 21-55, FLOORBEAM TEE HAS AREAS OF CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM 51-10-02. REMOVED DAMAGED TEE AND PERFORMED INSPECTIONS. LOCATED AND DRILLED REPAIR PARTS. TREATED, PRIMED, PAINTED AND INSTALLED REPAIR PARTS IAW ECRA 5310-0553 6, SRM 51-40-02 AND DWGS 146N5230, 146N5252 AND 146N5230.