What was found
MAIN CABIN FLOOR SUPPORT WEB UPPER ATTACH ANGLE HAS CRACKS AROUND FASTNER HOLES BS 780 TO 800, BL 0. R & R FLOOR SUPPORT IAW DWG 140N3505 AND SRM 51-40-02, PAR 7C AND 53-00-51, FIG 201. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR SUPPORT WEB UPPER ATTACH ANGLE HAS CRACKS AROUND FASTNER HOLES BS 780 TO 800, BL 0. R & R FLOOR SUPPORT IAW DWG 140N3505 AND SRM 51-40-02, PAR 7C AND 53-00-51, FIG 201. MAJOR REPAIR.