What was found
U-CHANNEL CRACKED CABIN FLOOR LEVEL BS 700, BL LBL 45. R & R U-CHANNEL IAW SRM 51-40-02, PARA 7, FIG 12 AND DWG 143N5130. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
U-CHANNEL CRACKED CABIN FLOOR LEVEL BS 700, BL LBL 45. R & R U-CHANNEL IAW SRM 51-40-02, PARA 7, FIG 12 AND DWG 143N5130. MAJOR REPAIR.