As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT PACK COMPRESSOR OUTLET DUCT SPLIT AT COMP OUTLET TEMP SENSOR BOSS. REPLACED DUCT ASSY, LEAK CHECKED AND TESTED IAW MM 21-51-00 PG 501 ALL GOOD. REPLACED ELBOW FITTING & ACCOMPLISHED PACK TEST WRT MM. ALL INDICATIONS CHECKED OK. ALSO LEAK CHECK ACCOMPLISHED, NO LEAKS FOUND.