What was found
FLOORBEAM AT FORMER FS 378 HAS CORROSION. MAINTENANCE REMOVED CORROSION AND FABRICATED REPAIR ANGLE FROM 2024-T3 .063 INCH IAW ENGINEERING REPORT NR 98-057. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT FORMER FS 378 HAS CORROSION. MAINTENANCE REMOVED CORROSION AND FABRICATED REPAIR ANGLE FROM 2024-T3 .063 INCH IAW ENGINEERING REPORT NR 98-057. (X)