ORD - FLT 5711 - NR 2 ADC FAILED IN FLIGHT. MAINTENANCE INSPECTED AND FOUND STATIC QUICK DISCONNECT LOOSE ON NR 2 ADC. RESECURED QUICK DISCONNECT. SYSTEM OPS CHECKED GOOD. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ORD - FLT 5711 - NR 2 ADC FAILED IN FLIGHT. MAINTENANCE INSPECTED AND FOUND STATIC QUICK DISCONNECT LOOSE ON NR 2 ADC. RESECURED QUICK DISCONNECT. SYSTEM OPS CHECKED GOOD. (M)