What was found
SBN - INTERCOSTAL BETWEEN FLOORBEAM AT STATION 360FS AND 343FS HAS CORROSION AROUND NUTPLATE HOLE. MAINTENANCE REAMED OUT THE NUTPLATE HOLE TO .50 DIAMETER AND FABRICATED A STRAP OF 2024-T3, .063 THICK BY 4.00 LONG BY .75 WIDE. ALL WORK WAS DONE IAW ENGINEERING ORDER NR 99-091. AREA WAS ALODINED AND PRIMED. (M)