What was found
SBN - THE FLOOR SUPPORT AT STATION 378AS IS CORRODED. MAINTENANCE FABRICATED FLOOR SUPPORT AND INSTALLED. ALL WORK WAS DONE IAW BAE ATP SRM 51-40-00 AND 51-50-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SBN - THE FLOOR SUPPORT AT STATION 378AS IS CORRODED. MAINTENANCE FABRICATED FLOOR SUPPORT AND INSTALLED. ALL WORK WAS DONE IAW BAE ATP SRM 51-40-00 AND 51-50-00. (M)