Service difficulty report · Circuit Card · Urocop EC135P2

Difficulty date
October 9, 2017
Submitted
October 11, 2017
Operation
Air carrier
Aircraft
N253SA
Make and model
Urocop EC135P2
Aircraft serial
0890
Aircraft time
2,589 hours, 6,879 cycles
Part
Circuit Card
Part number
P5034001
Part serial
1000257006
Condition
Failed
Location
Nr 1 Generator
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 GENERATOR DISCONNECT ADVISORY LIGHT ILLUMINATED IN FLIGHT. FOUND THE NR 1 Z100 PC CARD IN MASTER CONTROL BOX HAD FAILED. REPLACED THE PC CARD IAW AMM 24-63-00, 8-3. SYSTEM OPS CHECKED GOOD. FAILURE OF CARD CAUSED A DIVERSION.

More about the Urocop EC 135 P2