As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DENT IN FWD FUSELAGE FR10 BETWEEN STR 17L AND STR 18L. NO DAMAGE TO FRAME OR STRINGER. THE DENTED AREA WAS 0.040" DEEP IN THE CENTER AND WAS 3.0 INCH LONG AND 0.600" WIDE. RE-CONTOURED DENTED AREA IAW IC2006-170/10082. NO CRACKS NOTED REF EMB NDT. REMOVED SHEAR CLIP TO FOM AND RE-INSTALLED IAW EMB 170 SRM 51-41-01/02. APPLIED ALODINE, PRIMER, AND PAINT IAW EMB SRM 51-23-04/05/06.