What was found
LEVEL 2 CORROSION AT FR 90 FLOOR CROSS BEAM AT FLOOR SUPPORT. REMOVED AND REPLACED GUSSET IAW EMB 170 SRM 51-42-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION AT FR 90 FLOOR CROSS BEAM AT FLOOR SUPPORT. REMOVED AND REPLACED GUSSET IAW EMB 170 SRM 51-42-02.