What was found
LEVEL 2 CORROSION RT CENTER FLOOR SUPPORT BETWEEN FR 89 AND 90. REMOVED AND REPLACED RT CENTER FLOOR SUPPORT BETWEEN FR 89-90 IAW EMB 170 SRM 51-40-02, 51-40-03, 51-41-01, AND 51-43-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION RT CENTER FLOOR SUPPORT BETWEEN FR 89 AND 90. REMOVED AND REPLACED RT CENTER FLOOR SUPPORT BETWEEN FR 89-90 IAW EMB 170 SRM 51-40-02, 51-40-03, 51-41-01, AND 51-43-03.