What was found
LEVEL 2 CORROSION LEFT CENTER FLOORBEAM UPPER SHEET BETWEEN FRAMES 85 AND 86. INSTALLED NEW UPPER SHEET STRAP ON LT CENTER FLOORBEAM BETWEEN FRAMES 85 AND 86 IAW EMB 170 SRM 53-23-03, 53-23-10, 51-21-01, 51-41-01, 51-43-01, 51-23-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION LEFT CENTER FLOORBEAM UPPER SHEET BETWEEN FRAMES 85 AND 86. INSTALLED NEW UPPER SHEET STRAP ON LT CENTER FLOORBEAM BETWEEN FRAMES 85 AND 86 IAW EMB 170 SRM 53-23-03, 53-23-10, 51-21-01, 51-41-01, 51-43-01, 51-23-06.