What was found
IN CRUISE FLIGHT RECEIVED HYD SYS 2 LO QTY. DECLARED EMERGENCY, LANDING UNEVENTFUL. FOUND E2 EDP LEAKING AT CASE, REMOVED AND REPLACED E2 EDP IAW EMB 170 MM 29-11-01. OPS AND LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IN CRUISE FLIGHT RECEIVED HYD SYS 2 LO QTY. DECLARED EMERGENCY, LANDING UNEVENTFUL. FOUND E2 EDP LEAKING AT CASE, REMOVED AND REPLACED E2 EDP IAW EMB 170 MM 29-11-01. OPS AND LEAK CHECK GOOD.