What was found
LEVEL 2 CORROSION POTABLE WATER SERVICE PANEL BOX, BOTH HORSE SHOW RETAINERS. REMOVED AND REPLACED RETAINERS IAW EMB 170 SRM 51-43-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION POTABLE WATER SERVICE PANEL BOX, BOTH HORSE SHOW RETAINERS. REMOVED AND REPLACED RETAINERS IAW EMB 170 SRM 51-43-02.