What was found
LEVEL 2 CORROSION ON FWD CARGO DOOR SILL. REMOVED UNSERVICEABLE SUPPORTING SQUARES AND MATCH DRILLED SERVICEABLE SUPPORTING SQUARES AND INSTALLED PRIMED AND PAINTED FASTENERS IAW EMB 170 SRM 51-41-01, 51-20-00, 51-23-05, AND 51-23-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION ON FWD CARGO DOOR SILL. REMOVED UNSERVICEABLE SUPPORTING SQUARES AND MATCH DRILLED SERVICEABLE SUPPORTING SQUARES AND INSTALLED PRIMED AND PAINTED FASTENERS IAW EMB 170 SRM 51-41-01, 51-20-00, 51-23-05, AND 51-23-06.