What was found
LEVEL 2 CORROSION RT UPPER CFI SEAT TRACK AT FR26, AND HAS SCRATCHES AND PAINT DAMAGE. BLENDED OUT CORROSION AT FR26 IAW EMB 170 SRM 51-10-03 AND IS WITHIN ALLOWABLE DAMAGE LIMITS IAW ETD 2011-170/01766 REV C. PERFORMED HFEC TO EFFECTIVE AREAS IAW NDR MANUAL, NO FURTHER INDICATIONS OR CRACKS NOTED. RESTORED TOP COAT IAW EMB 170 SRM 51-23-06.