What was found
LEVEL 2 CORROSION AT RT FLOORBEAM UNDER CUP HOLES, RT FRAME 88-89. REMOVED AND REPLACED RT BEAM AT FR 86 TO FR 89 IAW EMB 170 SRM 51-43-03 AND 51-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION AT RT FLOORBEAM UNDER CUP HOLES, RT FRAME 88-89. REMOVED AND REPLACED RT BEAM AT FR 86 TO FR 89 IAW EMB 170 SRM 51-43-03 AND 51-41-01.